Fire Tube Steam Boiler With 2 Ton

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Fire Tube Steam Boiler With 2 Ton
  • Supply Capacity : 10 units/month :Fire Tube Steam Boiler With 2 Ton
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • LTU Series - Radiant Infrared Gas-Fired Tube Heaters

    As an alternative, the radiant gas tube heaters were chosen. A hot water boiler system was installed to heat other parts of the new sports complex which, in addition to the practice field, includes a two-story structure with full basement for offices, locker rooms, a sauna, steam room, and weight-lifting facility.Get Price

  • Titanic's Propulsion Plant

    Therefore, in terms of boiler supply, we get 12,525/2.0 = 6,262 lbs/minute, or expressed in tons (2240 lbs/long-ton) per minute, we get 6,262/2240 = 2.8 tons of steam per minute being supplied from the 24 double-ended boilers. This is a supply rate of 6,262/24 = 260.9 lbs of steam per minute per boiler.Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    Fire tube boilers have low initial cost, and are more compacts. But they are more likely to explosion, water volume is large and due to poor circulation they cannot meet quickly the change in steam demand. For the same output the outer shell of fire tube boilers is much larger than the shell of water-tube boiler.Get Price

  • Fire Tube Boiler | Operation and Types of Fire Tube Boiler

    Feb 24, 2012 · Fire tube boiler is one of the most basic types of boiler and the design is also very old. It was popular in 18 th century. It was mainly used for steam locomotive engines. Operation of Fire Tube Boiler. Operation of fire tube boiler is as simple as its construction. In fire tube boiler, the fuel is burnt inside a furnace.The hot gases produced in the furnace then passes …Get Price

  • BOILER INTERVIEW QUESTION & ANSWER - ASKPOWERPLANT

    Nov 24, 2016 · Q.(B).What do you mean by IBR steam boiler. IBR Steam Boilers means any closed vessel exceeding 22.75 liters in capacity and which is used expressively for generating steam under pressure and includes any mounting or other fitting attached to such vessel,which is wholly or partly under pressure when the steam is shut off.Get Price

  • BOILER INTERVIEW QUESTION & ANSWER - ASKPOWERPLANT

    Nov 24, 2016 · Q.(B).What do you mean by IBR steam boiler. IBR Steam Boilers means any closed vessel exceeding 22.75 liters in capacity and which is used expressively for generating steam under pressure and includes any mounting or other fitting attached to such vessel,which is wholly or partly under pressure when the steam is shut off.Get Price

  • Ship History - USS KIDD

    Having transferred steam to both engine rooms from her only remaining boiler room, KIDD now made approximately 20 knots as she headed south toward Ulithi Atoll. The crew buried their dead at sea along the way on April 12. Upon reaching Ulithi, another devastating blow to morale was waiting for them. Lookouts spotted flags flying at half-mast.Get Price

  • Steam locomotive - Wikipedia

    A steam locomotive is a rail vehicle that provides the force to move itself and other vehicles by means of the expansion of steam.: 80 It is fuelled by burning combustible material (usually coal, oil or, rarely, wood) to heat water in the locomotive's boiler to the point when it becomes gaseous and its volume increases 1,700 times. Functionally, it is a steam engine on wheels.Get Price

  • How much coal is required to generate 1 MWH of electricity?

    Mar 09, 2017 · During installation of industrial steam boiler, 1-2 experienced engineering and technical personnel will be sent for the site representative for technical tests and installation instructions free of charge; processing the various problems arising in the course timely while installing. Fire Tube Steam boiler. 4 ton fire tube steam boiler. 10 Get Price

  • Babcock and Wilcox boiler: Parts, Working, Advantages

    The advantages of Babcock and Wilcox boiler are: The overall efficiency of this boiler is high. The steam generation rate is higher about 20 ton per hour at pressure 10 to 20 bars. The tubes can be replaced easily. The boiler can expand and contract freely. It is easy to repair maintenance and cleaning. Disadvantages of Babcock and Wilcox BoilerGet Price

  • Fire Tube Boiler | Operation and Types of Fire Tube Boiler

    Feb 24, 2012 · Fire tube boiler is one of the most basic types of boiler and the design is also very old. It was popular in 18 th century. It was mainly used for steam locomotive engines. Operation of Fire Tube Boiler. Operation of fire tube boiler is as simple as its construction. In fire tube boiler, the fuel is burnt inside a furnace.The hot gases produced in the furnace then passes …Get Price

  • Steam Locomotives (USA): History, Types, Photos, Facts

    Dec 17, 2021 · Mike: Short for a Mikado (2-8-2) steam locomotive. Pop valve: The safety or pressure release valve on a steam locomotive boiler. Quarter-locked: Condition of a steam locomotive when it is stopped so that the drive rods are directly aligned with the piston which does not allow for the locomotive to be moved. The two sides of a steam locomotive Get Price

  • Titanic's Propulsion Plant

    Therefore, in terms of boiler supply, we get 12,525/2.0 = 6,262 lbs/minute, or expressed in tons (2240 lbs/long-ton) per minute, we get 6,262/2240 = 2.8 tons of steam per minute being supplied from the 24 double-ended boilers. This is a supply rate of 6,262/24 = 260.9 lbs of steam per minute per boiler.Get Price

  • Steam Boiler: Working principle and Types of Boiler

    Feb 24, 2012 · As the water and steam both are in same vessel a fire tube boiler cannot produce steam at very high pressure.. Generally it can produce maximum 17.5 kg/cm 2 and with a capacity of 9 Metric Ton of steam per hour.. Types of Fire Tube Boiler. There are different types of fire tube boiler likewise, external furnace and internal furnace fire tube boiler.Get Price

  • Steam locomotive - Wikipedia

    A steam locomotive is a rail vehicle that provides the force to move itself and other vehicles by means of the expansion of steam.: 80 It is fuelled by burning combustible material (usually coal, oil or, rarely, wood) to heat water in the locomotive's boiler to the point when it becomes gaseous and its volume increases 1,700 times. Functionally, it is a steam engine on wheels.Get Price

  • Mini Steam Powered Generating Sets | Claverton Group

    Jan 27, 2010 · Steam power plant consisting of (1) Double cylinder double acting steam engine 10 hp, each cylinder dia 3″xstroke 4″, complete with reverse mechanism, hand lubricating pump for cylinder lubrication, drip lubricator for crosshead lubrication and 12″ pulley (2) Water tube Yarrow type boiler suitable for biomass firing with 90 sq ft heating Get Price

  • Secure Online Ordering - Marx Train Parts

    Frosted Lexan, 12" x 3", for repairing windows or replacing steam engine number boards: $2.00: 424: Plastic Ladder for the 065 water tower, specify gray, black, cream, red, or yellow Boiler Front Screw for Steam Engines : $0.25 each: 179: Hex head main side rod bolt for 333/1829 engines Sheet metal screw for steam engines and the 70 ton Get Price

  • How much coal is required to generate 1 MWH of electricity?

    Mar 09, 2017 · During installation of industrial steam boiler, 1-2 experienced engineering and technical personnel will be sent for the site representative for technical tests and installation instructions free of charge; processing the various problems arising in the course timely while installing. Fire Tube Steam boiler. 4 ton fire tube steam boiler. 10 Get Price

  • Steam Boiler: Working principle and Types of Boiler

    Feb 24, 2012 · As the water and steam both are in same vessel a fire tube boiler cannot produce steam at very high pressure.. Generally it can produce maximum 17.5 kg/cm 2 and with a capacity of 9 Metric Ton of steam per hour.. Types of Fire Tube Boiler. There are different types of fire tube boiler likewise, external furnace and internal furnace fire tube boiler.Get Price

  • Mini Steam Powered Generating Sets | Claverton Group

    Jan 27, 2010 · Steam power plant consisting of (1) Double cylinder double acting steam engine 10 hp, each cylinder dia 3″xstroke 4″, complete with reverse mechanism, hand lubricating pump for cylinder lubrication, drip lubricator for crosshead lubrication and 12″ pulley (2) Water tube Yarrow type boiler suitable for biomass firing with 90 sq ft heating Get Price

  • High-Performance HVAC | WBDG - Whole Building Design Guide

    Nov 07, 2016 · Indirect-fired units may use different sources for heat: hot water or steam from a boiler, steam from district heating, or waste heat in the form of water, air, or other gas. Absorption chillers can be single-effect or double-effect, where one or two vapor generators are used.Get Price

  • Babcock and Wilcox boiler: Parts, Working, Advantages

    The advantages of Babcock and Wilcox boiler are: The overall efficiency of this boiler is high. The steam generation rate is higher about 20 ton per hour at pressure 10 to 20 bars. The tubes can be replaced easily. The boiler can expand and contract freely. It is easy to repair maintenance and cleaning. Disadvantages of Babcock and Wilcox BoilerGet Price

  • Steam Locomotives (USA): History, Types, Photos, Facts

    Dec 17, 2021 · Mike: Short for a Mikado (2-8-2) steam locomotive. Pop valve: The safety or pressure release valve on a steam locomotive boiler. Quarter-locked: Condition of a steam locomotive when it is stopped so that the drive rods are directly aligned with the piston which does not allow for the locomotive to be moved. The two sides of a steam locomotive Get Price

  • PTS/PTU Series - Infrared Radiant Gas-Fired Tube Heaters

    As an alternative, the radiant gas tube heaters were chosen. A hot water boiler system was installed to heat other parts of the new sports complex which, in addition to the practice field, includes a two-story structure with full basement for offices, locker rooms, a sauna, steam room, and weight-lifting facility.Get Price

  • Used Stainless Steel Tanks 6,000 to 9,999 Gallons For Sale

    Fire Tube Package Boilers (9) Water Tube Package Boilers (55) 400 to 600 Ton Injection Molders (2) 600 to 2000 Ton Injection Molders (2) Blow Molders (17) Used approximately 6,000 gallon vertical 304 stainless steel tank Manufactured by Missouri Boiler 8′ diameter X 15′ straight side Dished top and bottom heads 60 psi/full vacuum Get Price

  • Essex class aircraft carrier CVA CVS US Navy

    2 x Mk 12 fire-control radar (later units) 2 x Mk 22 height-finding radar (later units) the boiler uptakes were rebuilt and angled aft to accommodate a single radar and communications mast atop the island. To better protect aircrews, ready rooms were moved from the gallery deck to below the armored hangar deck, with a large escalator on the Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    Fire tube boilers have low initial cost, and are more compacts. But they are more likely to explosion, water volume is large and due to poor circulation they cannot meet quickly the change in steam demand. For the same output the outer shell of fire tube boilers is much larger than the shell of water-tube boiler.Get Price

Discount
7X24 Online